ENG Operating Manual Light control PULSE PIR Vers.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Dear customer, Operating panels 3 General 4 - Safety instructions 4 The operating manual informs of additional adjustment possibilities on lights with PULSE PIR-control. The here described functions go beyond the general operation possibilities on the light and are usually rarely required. Operation 5 - Operation general 6 Please observe that the instructions may also describe functions, which are not available on each light.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Operating panels Sensor operating panel “PULSE PIR“ Menu structure “PULSE PIR - Vers. IV“ Functions Fig. 1 ON/OFF Change light level Change light level Note: The functions written in blue are not available.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ General Validity of these instructions Safety instructions These instructions apply to the following lights: Make sure to read the instructions for use before putting the light into operation! Caution, Take note of the accompanying documents! Please make sure to observe the safety instructions of the light operation instructions! Important information - Lights equipped with PULSE PIR from firmware vers. VFS 04.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Operation Fig. 2 LED II LED I Key I Key II Sensor Operating and display elements All operating and adjusting functions can be carried out from the sensor operation panel [fig. 2]. The functions and ajdustments are displayed at the sensor operating panel via both LEDs (I or II). In-factory setting The lights are set in-factory so that initially they can be operated without changing the settings.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Operation general Fig. 2 LED II LED I Key I Key II Sensor Operating elements Display Via the two keys [I and II] on the sensor, different functions can be activated depending on which key is pressed.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Operation Main functions Fig. 2 LED II LED I Switching on Press the switch I - the light changes to light level I. Press the switch II - the light changes to light level II. Key I Key II Sensor Switching off Briefly press the key on which the LED is lit - this will switch off the light. Change light level Briefly press the key on which the LED is not lit - this will switch the light to the other light level.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change basic settings - Part 1 Fig. 2 LED II LED I Key I Key II Sensor Change to parameterisation mode Keep both switches [I and II] pressed simultaneously for 10 seconds. - The operating panel changes to the parameterisation mode (first to setting level 1).
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change basic settings - Part 2 Fig. 2 LED II LED I Key I Key II Sensor Change setting Leave parameterisation mode The LED I indicates whether a function is active (ON) or inactive (OFF) by permanent lighting or flashing, e.g.: The parameterisation mode is left if no switch has been pressed for 10 seconds. The settings are stored.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ List of functions Fig. 2 The following functions can be selected: LED II LED I Key I Key II Sensor The bold-printed values are the in-factory defaults Level Function LED II LED I Designation 1 Function 1.1: flashing white green Background light ON/OFF 1 Function 1.2: flashing white red External activation ON/OFF 1 Function 1.3: flashing white blue Burn-In function ON/OFF 1 Function 1.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Change the setting level Fig.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 1 Fig. 2 LED II Actuation Display Press both keys for at least 10 seconds LED II flashes white LED I Activate setting level 1 Key I Key II LED II Sensor Function 1.1 Background light ON/OFF Release both keys LED I Change function from ON to OFF or vice versa Press key I LED I Note: Note: The functions written in blue are not available.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 1 (continued) Fig. 2 Actuation LED II Display LED I Activate function 1.2 Key I Key II Sensor LED I Activate function 1.3 LED I Activate function 1.4 LED I Activate function 1.5 LED I Activate function 1.6 LED I Note: The functions written in blue are not available. Activate function 1.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 2 Fig. 2 LED II Actuation Display Press both keys once for 10 seconds and once for 5 seconds LED II flashes red LED I Activate setting level 2 Key I Key II Sensor LED II Function 2.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 2 (continued) Fig. 2 Actuation LED II Display LED I Activate function 2.2 Key I Key II LED I Activate function 2.3 Sensor LED I Activate function 2.4 LED I Activate function 2.5 LED I Activate function 2.6 LED I Activate function 2.7 Note: The functions written in blue are not available.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 3 Fig. 2 Actuation LED II LED I Display Activate setting level 3 (function 3.1 - 3.6) Key I Key II Press both keys once for 10 seconds and twice for 5 seconds LED II Sensor Change function LED I Change function LED I Note: The functions written in blue are not available.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Change the basic settings - Setting level 4 Fig. 2 Actuation LED II LED I Display Activate setting level 4 (function 4.1 - 4.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 1) Fig. 2 LED II LED I Key I Key II Sensor Function 1.1 Function 1.2 Function 1.3 Background light External switching Burn-in function Function to switch the logo background light ON and OFF for lights with a column-operating panel (multifunctional switch). Function to operate the light via external switching elements. Function for burning in the lamps The function is basically set to “ON“.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 2) Fig. 2 LED II LED I Key I Key II Sensor Function 1.4 Function 1.5 Function 1.6 Write protection Light control Presence control Function for admission or avoidance of setting variations. Function for the automatic readjustment of the set brightness in case the ambient brightness changes. Function to detect the presence of persons. The default setting of the function is “OFF“, i.e.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 3) Fig. 2 Function 1.7 LED II LED I Demo mode Function to demonstrate and to test the light functions. Key I Key II Sensor The default setting of this function is “OFF“, i.e., the demo mode is inactive. All control times are working in the seconds range if the demo mode is switched on. Note: This mode is left automatically 10 minutes after the last key was pressed.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 4) Fig. 2 LED II LED I Key I Key II Sensor Function 2.1 Function 2.2 Function 2.3 Sensitivity high Switch-on automatic Dual sensors Function to change the sensitivity of the presence control. Function to admit or to suppress automatic switch-on with insufficient light or in case of presence (semi-automatic).
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 5) Fig. 2 LED II LED I Key I Key II Sensor Function 2.4 Function 2.5 Function 2.6 Sensor LED Continuous operation Parameter setting protection Function to switch both LEDs in the sensor operating panel on and off. Setting function for continuous operation. The default setting of the function is “ON“, i.e., the LEDs in the light head are switched on. The default setting of the function is “OFF“.
ENG Operating manual Light Control „PULSE PIR - Vers. IV“ Explanation of the functions (part 6) Fig. 2 LED II LED I Key I Key II Sensor Function 2.7 Function 3.1 - 3.6 Function 4.1 - 4.6 Special function Follow-up time Presence range The special function is not available. Function to adjust the time after which the light is to be switched off if no presence is detected. Function to set the detection range of the presence sensor. The function cannot be changed.
Order No. 405 170 110 - © copyright H.Waldmann GmbH & Co. KG - nB / 05.2011 - TB - Subject to modifications - Printed in Germany ENG 24 Operating manual Light Control „PULSE PIR - Vers.