GB Operating Manual Light control PULSE HFMD Vers.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Dear customer, this operating manual applies in addition to the instructions for use of the light. Please observe in particular the safety instructions stated in the instructions for use! The operating manual informs of additional setting options on lights with PULSE HFMD control. The functions described here go beyond the general operating options on the light and are usually rarely required.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Operating panels Column operating panel „MFT“ Fig. 1 Menu structure “PULSE HFMD - Vers.
GB Operating Manual Light control “PULSE HFMD - Vers.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Operation Fig.3 (Column operating panel) LED I Key I Logo Light bar Key II LED II Fig. 4 (Sensor operating panel) LED II LED I Operating and display elements All operating and setting functions can be carried out from the column operating panel (Fig. 3) as well as from the sensor operating panel (Fig.4).
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Operation general Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Operation Main functions Fig. 3 Switching on Press the key I - this will switch on light level I. LED I Key I Logo Light bar Key II LED II Press the key II - this will switch on light level II. Switching off Briefly press the key on which the LED is lit - this will switch off the light. Change level Briefly press the key on which the LED is not lit - this will switch the light to the other light level.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings Fig. 3 Change to parameterization mode LED I Key I Logo Light bar Key II LED II - Keep both keys [I and II] pressed simultaneously for 2 seconds. - The operating panel changes to the parameterization mode (first to level 1). - The background lit logo flashes (once per second).
GB Operating Manual Light control “PULSE HFMD - Vers. III“ List of functions Fig. 3 The following functions can be selected: The bold-printed values are the in-factory defaults Function Light bar (Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Change setting level Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Level 1 Fig. 3 LED I Actuation Display Press both keys for at least 2 seconds Logo flashes white Sensor LED II flashes white Activate setting level 1 Key I Logo Light bar Function 1 Background light ON/OFF Logo flashes white Bar display dark green (LED 1) Key II LED II Change function from ON to OFF or vice versa Press key I Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Level 1 (cont.) Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Level 1 (cont.) Fig. 3 Actuation Activate function 8 LED I Switch-on automatic ON/OFF Press key II 7 times Key I Logo Activate function 9 Key II Activate function 10 Activate function 11 Logo flashes white Bar display LED 6+5+4+3+2 Demo mode ON/OFF Press key II 10 times Fig.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Level 2 Fig. 3 Actuation Display Activate setting level 2 (function 20) LED I Press both keys until the logo switches from flashing to OFF Key I Logo Light bar Change function Increase the follow-up time in stages Briefly press key I Key II LED II Fig. 6 Change function 14 2 3 4 5 6 The light bar shows the newly set follow-up time.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Change basic settings - Level 3 Fig. 3 Actuation Display Activate setting level 3 (function 30) LED I Press both keys until the logo switches from flashing to OFF and from OFF again to flashing. Key I Logo Light bar Change function Key II Increase presence range Briefly press key I LED II Fig. 6 Change function 2 3 4 5 The light bar shows the newly set presence range.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Explanation of the functions (part 1) Fig. 3 LED I Key I Logo Light bar Key II LED II Function 1 Function 2 Function 3 Background light External switching Synchronous control Function to switch the logo background light on and off. Function to operate the light via external switching elements. The default setting of the function is “ON“.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Explanation of the functions (part 2) Fig. 3 LED I Key I Function 4 Function 5 Function 6 Write protection Light control Presence control Function to admit or prevent setting variations. Function for the automatic readjustment of the set brightness in case the ambient brightness changes. Function to detect the presence of persons. Logo The default setting of the function is “OFF“, i.e., the set levels can be overwritten at any time.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Explanation of the functions (part 3) Fig. 3 LED I Key I Logo Light bar Key II LED II Function 7 Function 8 Function 9 Reduced sensitivity Switch-on automatic Special function Function to change the sensitivity of the presence control. Function to admit or to suppress automatic switch-on with insufficient light or in case of presence (semi-automatic). The special function is not available.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Explanation of the functions (part 4) Fig. 3 LED I Key I Logo Light bar Key II LED II Function 10 Function 11 Sensor LED Demo mode Function to switch both LEDs in the sensor operating panel on and off. Function to demonstrate and to test the light functions. The default setting of the function is “OFF”, i.e., the LEDs in the light head are switched off. The default setting of this function is “OFF“, i.e., the demo mode is inactive.
GB Operating Manual Light control “PULSE HFMD - Vers. III“ Explanation of the functions (part 5) Fig. 3 LED I Key I Function 30 Follow-up time Presence range Function to adjust the time after which the light is to be switched off if no presence is detected. Function to set the detection range of the presence sensor. Logo The default setting of the follow-up time is 10 min. Light bar 6 different follow-up times from 5 to 30 min can be set.
GB Operating Manual Light control “PULSE HFMD - Vers.
GB Operating Manual Light control “PULSE HFMD - Vers.
GB Operating Manual Light control “PULSE HFMD - Vers.
Order no. 405 171 110 - © copyright H.Waldmann GmbH & Co. KG - nB / 11.2006 - TB - Subject to modifications - Printed in Germany GB 24 Operating Manual Light control “PULSE HFMD - Vers. III“ Edition: 22.11.