AirQM-9 Instruction Manual This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Product Introduce Face Panel Status Indicator LCD Display Ambient light sensor Switching Button Specifications: Model AirQM-9 Size 150*66*49.2mm (non-include power plug) Net Weight Input Power 110~240V-0.1A, 50/60Hz Operation Ambient Indoor Use Only Temp:-10℃~60℃ Hum: 0-90% non-condensing Network Connection Wi-Fi IEEE 802.11b/g/n 2.
Operations Setup Insert the device to the power socket and the display show a ten-second countdown. The device starts to work normally when the countdown end. ⚫ Attention: To ensure the data accuracy of the measurement, please keep the device’s orientation as the picture and working in a well-ventilated place. Configuration Flash slowly Enter Network Configuration Mode Press the Switching Button for several seconds after power on, and release the button after buzzer is on.
Connect the Device with Mobile phone Enter WLAN setting of mobile phone, search Wi-Fi ‘airbox_device’ and select. Enter Network Configuration Interface After the mobile phone is connected to the device’s Wi-Fi, open the phone browser and input 192.168.4.1 in the address bar to enter configuration interface. Fill in the Configuration Information * Input Wi-Fi SSID, password and other * network configuration parameters in the Connect NetWork interface. And click the Config button to finish.
⚫ Attentions: 1. Special characters are not allowed when entering the configuration information. 2. The mark * are mandatory field, please fill in correctly. 3. The last input data will be the default configuration if the nonmandatory fields are not modified when changing the network connection setting.
Status Indicator Description: Temperature ●18℃~35℃, Green ●Out of range, Yellow Humidity 40%~85%, Green ● Out of range, Yellow● Illuminance ●30~500lux, Green ●Out of range, Yellow Noise Less than 80dB, Green● More than 80dB, Yellow● Smoke ●Less than 500ppm, Green ●500~1500ppm, Yellow ●More than 1500ppm, Red Carbon Dioxide Less than 1500ppm, Green ● 1500~3000ppm, Yellow ● More than 3000ppm, Red ● Particulate Matter 2.
Carbon Monoxide ●Less than 5ppm, Green ●5~35ppm, Yellow ●More than 35ppm, Red Volatile Organic Compound Less than 1.0ppm, Green ● 1~3ppm, Yellow ● More than 3ppm, Red ● ⚫ Attention: When the measuring value of CO, CO2 or Smo are out of range, the Status Indicator light up in red and buzzer alarm.
FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.