3.1.5.4 Example
Allocation can be clearly illustrated here by a fieldbus node with a coupler and
18 I/O modules.
Fig. 3-9: Application example g012234x
Master addresses *) No. I/O module
Inputs Outputs
1 Power supply --- ---
Digital input P32.0
Digital input P32.1
Digital input P32.2
2
Digital input P32.3
Digital input P32.4
Digital input P32.5
Digital input P32.6
3
Digital input P32.7
Digital input P33.0
Digital input P33.1
Digital input P33.2
4
Digital input P33.3
Analog input P20 5
Analog input P22
6 Power supply --- ---
Digital output P28.0
Digital output P28.1
Digital output P28.2
7
Digital output P28.3
Digital output P28.4
Digital output P28.5
Digital output P28.6
8
Digital output P28.7