Datasheet
3
257
3
Technical Data
Output:
Output signal Voltage:
0 ... 5 V, 1 ... 5 V, 0 ... 10 V, 2 ... 10 V
Current:
0 ... 10 mA, 2 ... 10 mA,
0 ... 20 mA, 4 ... 20 mA
Load impedance ≤ 600 (I output)
≥ 2 k (U output)
Conversion time Gate time measurement method
(> 400 Hz): < 20 ms
Pulse time measurement method
(< 400 Hz): < 200 s + T
Cycle duration
General specifications:
Voltage supply V
S
24 V DC
Supply voltage range 16.8 V ... 31.2 V
Current consumption at 24 V DC ≤ 40 mA
Transmission error ≤ 0.1 % of upper range value
Temperature coefficient ≤ 0.01 % /K
General Specifications
Environmental requirements:
Ambient operating temperature -25 °C ... +70 °C
Storage temperature -40 °C ... +85 °C
Safety and protection:
Test voltage (input/output/supply) 2.5 kV AC, 50 Hz, 1 min.
Connection and type of mounting:
Wire connection CAGE CLAMP
®
S
Cross sections solid:
0.08 mm² ... 2.5 mm² / AWG 28 ... 14
fine-stranded:
0.34 mm² ... 2.5 mm² / AWG 22 ... 14
Strip lengths 9 ... 10 mm / 0.37 in
Dimensions and weight:
Dimensions (mm) W x H x L 6 x 96 x 94
Height from upper-edge of DIN 35 rail
Weight 38.7 g
Standards and approvals:
Conformity marking 1
r UL 508
r ANSI/ISA 12.12.01 (pending)
Shipbuilding g
Accessories see pages 268 ... 271
Refer to following pages for DIP Switch Table and Pin Assignments.