Data Sheet
Data sheet | Item number:787-1002
www.wago.com/787-1002
06.12.2018Page /3 6
Fuse protection:
Internal fuse T 2 A / 250 VAC
External fuse (required) an external DC fuse required for DC input voltage
External fuse (recommended) Circuit breakers 6 A (characteristic: C), 10 A (characteristic: B) or
higher
Safety and protection:
Insulation voltage (PRI-SEC) 4.242 kV DC
Protection class II
Degree of protection IP20 (per EN 60529)
Feedback voltage ≤ 30VDC
Overvoltage category II
Transient protection, primary Varistor
Overvoltage protection, secondary ≤ 40 VDC (in case of an error)
Short circuit protection Yes
No-load proof Yes
Parallel operation Yes
Series connection Yes
MTBF >500,000h (per IEC 61709)
Connection data
Connection type (1) Input/Output
Connection technology
CAGE CLAMP
®
WAGO terminal WAGO 740 Series
Solid conductor 0.08 … 2.5 mm² / 28 … 12 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 12 AWG
Strip length 6 … 7 mm / 0.24 … 0.28 Inch
Geometrical Data
Width 54 mm / 2.126 inch
Height 89 mm / 3.504 inch
Depth 59 mm / 2.323 inch
Length from upper-edge of DIN-35 rail 55 mm / 2.165 inch
Mechanical data
Type of mounting DIN-35 rail (EN 60715)