Certificate

870 (2) 28-12
Sol/Str
Cu 2 N/A N/A N/A B, C,
D
2 (105) ,4, *
Note: (2) Followed by -687, -837, -907 or 917.
870-826 28-12
Sol/Str
Cu 2 N/A 300 20 B, C 2 (105) ,4, *
869 (1) 28-12
Sol/Str
Cu 2 N/A 600 20 B, C,
D
2 (105) ,4, *
Note: (1) Followed by -102 thru -112, -132 thru -142, -152 thru -162, -182 thru -192, -202 thru -212, -232 thru -242, -301,
-304, -309, -311, -314, -316, -319, -321, -324, -326, -329, -331, -334, -339, -341, -344, -349, -351, -354, or -359.
869 (2) 28-12
Sol/Str
Cu 2 N/A N/A N/A B, C,
D
2 (105) ,4, *
Note: (2) Followed by -307, -317, -327, -328, -337, -347 or -357.
880 (1) 28-12 Cu 2 N/A 300 20 B, C,
D
2 (105), #
880 (2) 28-12 Cu 2 N/A 600 20 B, C 2 (105), #
880 (3) 28-12 Cu 2 N/A — — — 2 (105), #
880 (4) 28-12 Cu 2 N/A 300 20 B, C,
D
2 (105), 5, #
880 (5) 28-12 Cu 2 N/A 600 20 B, C 2 (105), 5, #
880 (6) 28-12 Cu 2 N/A — — — 2 (105), 5, #
Note: (1) Followed by -661, -662, -664, -861, -862, -864, -961, -962, -964.
Note: (2) Followed by -681, -682, -684, -831, -832, -834, -901, -902, -904.
Note: (3) Followed by -687, -837, -907.
Note: (4) Followed by -661, -662, -664, -861, -862, -864, -961, -962, -964 with suffix no. /999-940.
Note: (5) Followed by -681, -682, -684, -831, -832, -834, -901, -902, -904 with suffix no. /999-940.
Note: (6) Followed by -687, -837, -907 with suffix no. /999-940.
744 20-16 Cu 2 N/A 300 2 B 2 (105), 4
* or # Unique Conditions of Acceptability — i.e. This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for
branch circuit overcurrent protection. Markings concerning fuse replacement and location should be considered. Refer to report for additional
information.
Cat. No.
Wire
Range WT FW
Torque
Lb In. V A UG CA
2010-1201, 2010-1204, 2010-1202, 2010-1207, 2010-1301,
2010-1304, 2010-1302, 2010-1307 (3)
20-6 Cu 2 N/A 600 65 B,
C
2 (105),4, 6
(12 x 10 x
8.25)
2010(1)(3) 20-6 Cu 2 N/A 600 65 B,
C
2 (105), 4
2010(2)(3) 20-6 Cu 2 N/A — — B,
C
2 (105), 4
Note: (1) Followed by 12, 13, followed by 01 thru 06, 08 or 09
Note: (2) Followed by 12, 13, followed by 07
Note: (3) May be followed by /000-014 or /000-015.
2016(1) 20-4 Cu 2 N/A 600 85 B,
C
2 (105), 4
2006-1601, 2006-1602, 2006-1603, 2006-1604 20-8
sol/str
Cu 2 N/A 600 30 B,
C
2 (105), 4,
6 (12 x 10 x
8.25)
2006-1671, 2006-1672, 2006-1673, 2006-1674 20-8
sol/str
Cu 2 N/A 600 30 B,
C
2 (105), 6
(12 x 10 x
8.25)
2006-1671/1000-848 20-8
sol/str
Cu 2 N/A 24 30 B,
C
2 (105), 4
2006-1671/1000-849, 2006-1681/1000-414, 2006-
1681/1000-435)
20-8
sol/str
Cu 2 N/A 48 30 B,
C
2 (105), 4
2006-1671/1000-850 20-8
sol/str
Cu 2 N/A 120 30 B,
C
2 (105), 4
2006-1671/1000-851 20-8
sol/str
Cu 2 N/A 230 30 B,
C
2 (105), 4
2006-1681, -1682, -1683, -1684 20-8
sol/str
Cu 2 N/A 600 30 B,
C
2 (105)
Page 3
5
of 4
2
XCFR2.E45172 - Terminal Blocks - Component
29.01.201
6
htt
p
://database.ul.com/c
gi
-
b
in/XYV/tem
p
late/LISEXT/1FRAME/show
p
a
g
e.html?na
m
...