Certificate

711-131, 711-151,
711-171, 711-181
28-12 Cu 2 N/A 600 20 B,
C
2 (105), 4,
*
711-191 thru 711-194 (3) 28-12 Cu 2 N/A 600 10 B,
C
2 (105), 4,
*
711-401 thru 711-404(4) 28-12 Cu 2 N/A 600 10 B,
C
2 (105), 4,
*
711-405 thru 711-408(5) 28-12 Cu 2 N/A 600 10 B,
C
2 (105), 4,
*
Note: (1) For magnet wire range 0.2-1.9 mm only.
Note: (2) For magnet wire range 0.2-3.7 mm only.
Note: (3) For miscellaneous fuses 5 by 20 mm.
Note: (4) For miscellaneous fuses 6.35 by 32 mm.
Note: (5) For miscellaneous fuses 6.35 by 25 mm.
801-401, 801-402 18-16 Cu 2 N.A. 600 10 B,
C,
D
2 (105), 4,
*
801-601, 801-602, 801-605, 801-606 18-14 Cu 2 N.A. 600 10 B,
C,
D
2 (105), 4,
*
826-159 thru 826-172 28-12 Cu 2 N/A 300 20 B,
C,
D
2 (105), *,
6 (12 x 10
x 8.25)
828-(3) 16-6 Cu 2 N/A 600 40 B,
C
2 (105), 4,
6 (12 x 10
x 8.25)
283-601, 283-604 6-24 Cu 2 600 65 C 2 (105) * 6
(12 x 10 x
8.25) ##
Note: (3) Followed by suffix 263, 264, 265, 161, 162, 166, 167, 168, 251, 252, 253, 254, 255, 256, 257, 258, 261, 262, 266,
267, 268, 271, 272, 273, 274, 275, 276, 277, 278, 321, 322, 323, 324, 325, 326, 327, 328, 331, 332, 333, 334, 335, 336,
337, 338, 341, 342, 343, 344, 345, 346, 347, 348, 351, 352, 353, 354, 355, 356, 357 or 358 followed by suffix 002, 004, 005,
006, 009, 012, 016, 023 or 050, followed by /3AB-000 (where A and B is digit from 1 to 8).
Model/
Series/Types
Wire
Range WT FW
Torque
Lb In. V A UG CA
226+ 24-12 Cu 2 600 20 B, C,
D
2 (105), *
227+ 26-12 Cu 2 600 20 B, C,
D
2 (105), *
228+ 24-12 Cu 2 600 20 B, C,
D
2 (105), *
281-530, 281-531, 281-
532
28-12 Cu 2 N/A 600 20 B, C 2 (105), *, 6 (12 x 10 x
8.25)
862 (1) 22-12
Sol/Str
Cu 2 N/A 300, 600
(2)
20 B, C 2 (120), 4, 6 (12 x 10 x
8.25)
22-12
Sol/Str
Cu 2 N/A 600 (A) D 2 (120), 4
Note: (1) Followed -0 thru -9, followed by 5, 6, 7, followed by 0 thru 9, followed by 2 thru 5, followed by /0 thru /9, followed by
0, 3, followed by 00-0000 thru 99-9999.
Note: (2) 600 V when each wired terminal is surrounded by not used adjacent terminals. If metal screws are used for mounting
the terminal blocks, it needs to be installed on a suitable insulated mounting surface.
Note: (A) These limited ratings are applicable to a terminal block for use in or with industrial control equipment whereby the
load on any single circuit of the terminal block does not exceed 15 A at 51-150 V, 10 A at 151-300 V, or 5 A at 301-600 V, or
the maximum ampere rating, whichever is less.
834 (2) 8 Sol Cu 2 N/A 600 50 B, C 2 (115), 4, *
8-2 Str Cu 2 N/A 600 105 B, C 2 (115), 4, *
Note: (2) Followed by -1202, -1203, -1204, -1205, 1206, -1207, 1208, -1102, -1103, -1104, -1105, -1106, -1107 or -1108.
870 (1) 28-12
Sol/Str
Cu 2 N/A 300 20 B, C 2 (105), 4, *, 6 (12 x 10
x 8.25)
28-12
Sol/Str
Cu 2 N/A 600 5 D 2 (105), 4, *, 6 (12 x 10
x 8.25)
Note: (1) Followed by -101, -102, -103, -104, -108, -109, -117, -127, -501, -502, -503, -504, -508, -509, -517, -527, -531,
-533, -534, -535, -536, -538, -539, -551, -553, -556, -558, -559, -567, -577, -681, -682, -684, -831, -832, -834, -901, -902,
-904, -911, -912, or -914.
Page 3
4
of 4
2
XCFR2.E45172 - Terminal Blocks - Component