operation manual

GB
28
W 400
Problem Cause Remedy
Poor covering
capacity on the wall
Spray material is too cold
Highly absorbent surface or paint
with poor covering capacity
Distance too large
The material you are
spraying should be at
room temperature
Cross spray (Fig. 8)
Closer to the object
21. Technical Data
Technical Data
Max. viscosity 3400 mPas
Power source 230 V,
~ 50 Hz / 240 V,
~ 50 Hz
Power consumption 460 W / 485 W
Atomizing output 110 W
Max. ow rate 230 ml/min
Protection Class: I
Sound pressure level* 81 dB (A); Uncertainty K = 3 dB
Sound pressure output* 92 dB (A); Uncertainty K = 3 dB
Oscillation level* < 2.5 m/s²; Uncertainty K = 1.5 m/s²
Weight 1.7 kg
* Measured in accordance with EN 60745-1
Information about the oscillation level
The specied oscillation level has been measured according to a standard test
procedure and can be used to compare against electric tools.
The oscillation level is also for determining an initial assessment of the vibrational
strain.
Attention! The vibration emission value can dier from the specied value when the
electric tool is actually in use, depending on how the electric tool is being used. It is
necessary to specify safety measures to protect the operating personnel. These measures
are based on an estimated shutdown during the actual conditions of use (all parts of the
operating cycle are taken into consideration here, for example periods when the electric
tool is switched o, and, when it is switched on but running without any load).