Technical data

44
Super Finish 7000
1
GB
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump or spray in container
with small opening (bunghole)!
See safty regulations.
5. Fill up hopper with suitable cleaning agent.
6. Open relief valve
valve position
(circulation)
7. Pump suitable cleaning agent in the circuit for several mi-
nutes.
8. Close relief valve,
valve position (spraying)
9. Pump the remaining cleaning agent from the hopper,
high-pressure hose and the spray gun into an open con-
tainer
10. Open relief valve
valve position (circulation)
11. Switch o unit
8.1 CLEANING THE UNIT FROM THE OUTSIDE
First unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingression! Never spray down the unit with
high-pressure or high-pressure steam clean-
ers.
The suction hose is only solvent-resistant to
a limited extent. Do not immerse in solvent,
only wipe.
Wipe down unit externally with a cloth which has been im-
mersed in a suitable cleaning agent.
8.2 SUCTION FILTER
Clean lters always ensure maximum volume,
constant spray pressure and problem-free
functioning of the unit.
Device with exible suction
system (accessory)
1. Unscrew the lter (Item 1)
from the suction tube (2).
2. Disassemble lter by rotat-
ing the base (3).
3. Clean or replace the lter.
Carry out cleaning with
a hard brush and a corre-
sponding cleaning agent.
8.3 HIGHPRESSURE FILTER
1. Open relief valve
valve position (circulation) - Switch the unit o.
2. Open the high-pressure lter and clean the lter insert. To
do so:
3. Unscrew the lter housing (1) by hand.
4. Remove the lter insert (2) and pull out the bearing spring
(3).
5. Clean all the parts with the corresponding cleaning agent.
If compressed air is available blow through the lter in-
sert and bearing spring.
6. When mounting the lter ensure that the bearing ring (4)
in the lter insert is positioned correctly and check the O-
ring at the lter housing for damage.
7. Screw on the lter housing by hand until it stops (a higher
tightening force only impedes later dismantling).
1
3
2
Device with rigid suction system
1. Unscrew the lter (Item 1) from
the suction tube.
2. Clean or replace the lter.
Carry out cleaning with a hard
brush and a corresponding clea-
ning agent.
Unit with hopper
1. Release screws with a screwdriver.
2. Lift and remove lter disk with a screwdriver
3. Clean or replace the lter disk.
Carry out cleaning with a hard brush and a corresponding
cleaning agent.
cleanIng the unIt