Technical data

45
Plast Coat 15
EDITION 09 /2004
GB
7
1 6
2
8
3
5
4
7.6 EXTENSION CABLE
7.7 PREPARING THE MORTAR SPRAYING MACHINE
Recommended lubricant for the mortar hose
Water is not a satisfactory lubricant.
Danger of blockages!
Synthetic resin products –> synthetic resin
dispersion
PCC systems –> cellulose paste
Fill 2–3 l synthetic resin dispersion or cellulose pasteinto the
receptacle.
Caution: set changeover switch (4, fig. 15) to „0“ before tur-
ning on the master switch (1, fig. 15).
Turn master switch (1, fig. 15) to „1“, the indicator lamp will
show that the machine is ready for operation.
Set feed rate regulator (3) to „5“.
Turn changeover switch (4) to „AUTO“ (remote control
using spray lance).
3
4
1
2
Hold spray lance over an empty bucket.
7.8 SPRAY LANCE WITH AUTOMATIC CONTROL
Open material tap (3, fig. 16) on the spray lance. Themortar
spraying machine will switch on.
7.9 SPRAY LANCE WITHOUT AUTOMATIC CONTROL
Open material tap (3, fig. 17) on the spray lance. Press remote
control switch (1, fig. 17). The mortar spraying machine will
switch on..
7.10 SPRAY LANCE WITH AUTOMATIC CONTROL
When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose turn off device, turn
switching sleeve (1, fig. 16) by 90° in a clockwise direction as
far as it will go.
Close material tap (3, fig. 16).
7.11 SPRAY LANCE WITHOUT AUTOMATIC CONTROL
When the synthetic resin dispersion or cellulose paste has
been pumped into the mortar hose turn off device with
remote control switch (1, fig. 17).
Close material tap (3, fig. 17).
Check viscosity of the coating material.
Fill coating material into the receptacle. With mineral coa-
ting materials only fill the receptacle to half full.
The cross section of the cable must be
min. 3 x 2.5 mm
2
.
Unwind extension cable completely. Make
sure that the couplings and plugs are in com-
plete working order.
Arrange the mains cable so that there is no
danger of it being tripped over.
Protect against damage, e.g., caused by it
being run over.
Before connecting to the mains make sure that the mains
voltage is in accordance with the details on the rating plate.
Only connect to the mains supply using a special distribu-
ting point, e.g., using a side distribution system with fault
current protection with INF 30 mA.
Connect mortar spraying machine to the mains supply.
14
15
PLACING INTO OPERATION