Full Product Manual

1
k
PAGE 7
2
3
4
5
0
p
14
EN
CLEANUP
CLEANING NOTES - READ BEFORE CLEANING
When using latex material, clean sprayer and components with
warm, soapy water. For oil based material use mineral spirits.
Never use mineral spirits with latex materials.
NEVER use gasoline to clean sprayer.
Dispose of used cleaning solution properly.
Thorough cleaning and lubrication of sprayer is important to
ensure proper operation after storage.
If you ush your sprayer with mineral spirits, repeat Cleanup
instructions using warm, soapy water.
DO NOT SPRAY PUMP ASSEMBLY WITH WATER OR CLEANING
SOLUTION.
YOU WILL NEED
Warm, soapy water if using latex material
Mineral spirits if using oil-based material
Empty waste container
Soft-bristled brush
1. Perform Pressure Relief Procedure (page 7).
2. Remove the tip guard from the spray gun.
3. Empty the tank of spray material (see Moving / Emptying the
Sprayer, page 7.
Rinse the tank with the appropriate cleaning solution until clean.
Dispose of the cleaning solution, and then ll the tank again with
NEW cleaning solution. Do not run the sprayer without spray
material or water in the tank.
4. Remove the spray tip from the tip guard. Carefully place both into
the tank full of cleaning solution.
i
Allowing the spray tip and tip guard to soak in the
tank while ushing will make it easier to clean them
afterwards.
Take care not to lose the saddle seat and washer
located inside the rear of the spray guard.
5. Point the spray gun at the side of a waste container.
Ground the gun against the side of a metal waste
container if ushing with mineral spirits.
DO NOT SPRAY THE PUMP ASSEMBLY WITH
WATER OR CLEANING SOLUTION.
While squeezing the trigger, turn the sprayer ON (l), and turn the
PRIME/SPRAY knob to SPRAY.
Continue squeezing the trigger until uid is coming out clear.
You may need to get new cleaning solution and repeat.
The spayer will not spray air. It must have spray material or water
in the tank.
(Continued on the next page)
FOLLOW THESE STEPS WHENEVER CLEANING WITH MINERAL SPIRITS:
If spraying or cleaning with oil-based materials, the spray gun
must be grounded while preparing the spray hose or cleaning.
Ground the gun by holding it against the edge of a metal
container while purging. Failure to do so may lead to a static
electric discharge which may cause a re.
Always ush spray gun at least one hose length from spray
pump.
If collecting ushed solvent in one gallon metal container, place
it into an empty ve gallon container, then ush.
Area must be free from vapors.
Follow all cleanup instructions.