User manual
7
HandiRoll 550 GB
CLEANUP
When cleaning the HandiRoll 550, it is very important that you use the appropriate
cleaning solution for the type of paint you are using.
Turn the switch on the main tube to 10. FILL. Pull plunger back to draw remaining paint
from roller arm into the tube
Press ll valve onto ll tube. Push plunger forward to return excess paint to can.11.
Press locking tab and remove roller cover (a) assembly from the arm. Insert thumb to 12.
rst knuckle, pry and pull the cap (b) from the roller cover. Once the cap is removed,
push the roller core out the other end. Clean with the appropriate cleaning solution.
Remove ll tube from the clip and insert it into the ll valve. Submerge ll tube into 13.
appropriate cleaning solution. Pull/push plunger 5 times. Remove ll tube from the
ll valve.
Submerge ll valve and roller arm into cleaning solution. Pull/push plunger 5 times 14.
Remove the roller arm.
Submerge the connecting area and the ll valve into cleaning solution. Pull/push
15.
plunger 5 times.
STORAGE
Turn the locking collar next to the trigger counterclockwise until the main tube slides 16.
o the plunger.
Pack a generous amount of petroleum jelly around and in between the O-rings on
17.
the plunger.
Clean and pack a generous amount of petroleum jelly on the seal (a), O-ring (b) and 18.
other indicated bearing areas (c) of the arm.
PROBLEM CAUSE SOLUTION
A. There is paint
leakage on the roller
arm assembly
The seal on the arm is 1)
backward
The seal and cap were not 2)
properly cleaned
The O-ring and the 3)
connecting area were not
cleaned properly.
Paint residue on connecting 4)
areas
The O-rings are damaged or 5)
missing
The roller cover is worn or 6)
damaged
The core or cap is worn or 7)
damaged
The bearing areas are worn8)
Turn the seal around 1)
Clean and properly 2)
lubricate
Clean and properly 3)
lubricate
Clean connecting areas 4)
Replace the O-rings 5)
Replace roller cover 6)
Replace core or cap 7)
Call customer service8)