Cleanup (continued)
Cleaning the Nozzle 
To Clean the Nozzle:
 1.  Make sure power cord is unplugged. Remove the air 
hose from the turbine.
 2.  iSpray nozzle only - 
  a.  Remove the adjustment ring (a) carefully from the 
connecting nut (b). Loosen the connecting nut.
  b.  Remove the parts as shown. Clean all parts with a 
cleaning brush and the appropriate cleaning solution.
    To reassemble, see the instructions on the next page. 
 3.  Detail Finish nozzle only -
  a.  Unscrew the nut and remove the air cap and nozzle.
    Remove the parts as shown*. Clean all parts with a 
cleaning brush and the appropriate cleaning solution.
    Reassemble all parts when clean**.
 4.  Clean the air vent (c) on the suction tube with a soft 
bristled cleaning brush. 
 5.  Push the tab below the trigger, twist and separate the 
nozzle from the handle.
    Clean the rear of the nozzle (d) with the appropriate 
cleaning solution. Use a thin layer of petroleum jelly to 
lubricate the O-ring (e).
(a)
(b)
2a
1
(c)
(d)
(e)
2b
4
5
3a
Nozzle seal (Detail Finish nozzle only)
(*) The nozzle seal may 
become stuck inside the 
Detail Finish nozzle when 
the nozzle is removed. If this 
occurs, make sure to pull it 
out. 
(**) It is important that the nozzle 
seal inside the nozzle be re-installed 
properly. Make sure the cup side of 
the seal (the side with the groove) is 
facing out towards the front of the 
nozzle. Improper installation will cause 
leakage and damage to the turbine. 
Groove