Section 8- Exposure Controls, Personal Protection
(a)Control parameters
Exposure Guidelines
Chemical
Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt
Oxide
(LiCoO2)
12190-79-3
TWA: 0.02 mg/m3
Aluminum
7429-90-5
TWA: 1 mg/m3
respirable fraction
TWA: 15 mg/m3 total dust
TWA: 5 mg/m3 respirable fraction
(vacated) TWA: 15 mg/m3 total dust
(vacated) TWA: 5 mg/m3
respirable fraction (vacated)
TWA: 5 mg/m3 Al Aluminum
TWA: 10 mg/m3 total dust
TWA: 5 mg/m3 respirable
dust
Copper
7440-50-8
TWA: 0.2 mg/m3
fume
TWA: 1mg/m3 Cu
dust and mist
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and mist
(vacated) TWA: 0.1 mg/m3 Cu
dust, fume, mist
IDLH: 100 mg/m3 dust,
fume and mist
TWA: 1 mg/m3 dust and
mist
TWA: 0.1 mg/m3 fume
Phosphate(1-),
hexafluoro-,
lithium
21324-40-3
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 dust
(vacated) TWA: 2.5 mg/m3
ACGIH TLV: American Conference of Governmental Industrial Hygienists -Threshold Limit Value OSHA PEL: Occupational
Safety and Health Administration - Permissible Exposure Limits Immediately Dangerous to Life or Health
Other Exposure Guidelines: Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA,
965 F.2d 962(11th Cir., 1992) See section 15 for national exposure control parameters
(b) Appropriate engineering controls
Engineering Measures: 1.Showers 2.Eyewash stations 3.Ventilation systems
(c) Individual protection measures, such as personal protective equipment
Respiratory protection: No necessary under normal use. In case electrolyte leakage from the battery, protect
hand with chemical resistant rubber gloves. If battery is burning, leave the area
immediately. In abuse, use NIOSH approved acid gas filter mask or self-contained
breathing apparatus.
Hand protection: None under normal use. In case of spilling, use PVC, neoprene or nitrile gloves of 15miles
(0.015 inch) or thicker.
Eye/Face protection: None required under normal conditions. Use approved chemical work safety goggles or f
ace shield, if handling a leaking or rupture battery.