Product Manual

Proline 5000
Inverter by Wagan Tech
®
7
www.wagan.com
INVERTER OUTPUT CHARACTERISTICS
The high output terminals and outlets of this inverter are wired in a similar manner to that of
house-hold wiring.
REAR PANEL
Ground
Terminal
Negative (
–) DC
Input Terminal
High Speed
Cooling Fan
Positive (+) DC
Input Terminal
High-Speed Cooling Fan
The fan operates automatically when the internal temperature of the inverter requires cooling.
Always allow free air flow. Do not block vents.
Negative DC () Input and Positive DC (+) Input Terminals
The extra-large blade terminals allow enough room to connect multiple DC cables.
Ground Terminal
This terminal is for attaching a 6 gauge insulated safety ground wire. This safety wire protects
personnel if there is an unlikely failure in either the cabling or enclosure insulation. Follow the
installation procedure.
PLANNING THE INVERTER SYSTEM
Any large wattage inverter system requires planning before installation. There are several steps
to the planning process so the user must determine the following:
Maximum inverter wattage required.
Operating time (run time) needed between battery recharges.
Battery bank capacity in amp-hours.