Product Manual

©2016 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
User’s ManualRead before using this equipment
www.wagan.com
14
DISPOSAL/RECYCLING OF INVERTER
Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.
SPECIFICATIONS
All specifications are typical at nominal line, half load and 77ºF unless otherwise
noted. Specifications are subject to change without notice.
Name Description
Input #3722 — 11-15V DC Input
#3722-4 — 21-30V DC Input
#3722-8 — 42-60V DC Input
AC Output 115 V
Output frequency 60 Hz
Output waveform Modified Sine Waveform
TrueRated
Power
(24-hour continuous)
1,500 Watts
Surge Power 3,500 Watts
Efficiency Max. 90%
No load current < 0.95 Amps
Low battery alarm #372210.5V ± 0.5V DC
#3722-4 — 21.0V ± 1.0V DC
#3722-8 — 42.0V ± 2.0V DC
Low battery automatic shutdown #37229.5V ± 0.5V DC
#3722-4 — 20.0V ± 1.0V DC
#3722-8 — 40.0V ± 2.0V DC
Alarm and thermal shutdown 130 ºF ± 1
AC Outlets
3x NEMA 5-15 USA
USB Outlets 3.0A shared
Dimensions (L x W x H) inches
11. 7 × 5.2 × 2.6 (in.)
Net Weight (includes cables)
5.2 lbs.