Technical data
PerfectCharge Using the IU0U automatic charger
49
Devices with temperature sensors (accessory)
The charging voltage is adjusted according to the battery temperature. A
temperature sensor can be connected for an optimum charging function. The
charging voltage is increased or reduced according to the battery tempera-
ture (see diagram):
10.4 Functional check
The charging of the batteries can be monitored by means of an LED on the
front of the device:
LED Battery charge status
I Phase Between 10% and 50%
U0 Phase Between 50% and 90%
U Phase Above 90%
16/32 V
-10 0 +10 +20 +30 +40
°C
U1
U2
15/30 V
14/28 V
13/26 V
12/24 V
_PerfectCharge_IU152A-IU254A.book Seite 49 Mittwoch, 26. März 2008 4:48 16