Technical data
Connecting the IU0U automatic charger PerfectCharge
44
Connecting the battery cables to the IU0U automatic charger
I
Note
The IU0U automatic charger's connections are suitable for cables
with cross-sections of 10 mm² to 25 mm².
➤ Fit wire sleeves to the ends of the cables to ensure permanent contact.
➤ Connect the positive battery cable to the respective slot:
– Supply battery: “BATT 1+”, “BATT 2+”, “BATT 3+”
– Starter battery: “START BATT +” (IU152A), “BATT 1+” (IU154A,
IU252A)
➤ Connect the negative battery cable or earth cable to the respective slot:
– Supply battery: “BATT –”
The following instructions apply to all cables accordingly:
➤ Fit cable sleeves on the ends of the cables (4).
➤ Undo the safety bolt (3) slightly.
➤ Insert the cable sleeves (4) in the slots provided.
➤ Retighten the safety bolt (3).
Connecting batteries
➤ Connect batteries according to the circuit diagram of your IU0U automatic
charger.
Closing the IU0U automatic charger
➤ Refit the rear panel (1) and fasten it with the screws (2).
9.2 Connecting the 230 V power cable
➤ Connect the 230 V connection cable (fig. 1 3, page 3) to the 230 V con-
nection (fig. 3 1, page 4) of the IU0U automatic charger.
➤ Insert the plug of the 230 V connection cable (fig. 1 3, page 3) to an
earthed socket which is protected by a residual current circuit breaker.
_PerfectCharge_IU152A-IU254A.book Seite 44 Mittwoch, 26. März 2008 4:48 16