Technical data

EN
CFX35 – CFX65DZ Operation
37
In “HIGH” mode, the battery monitor responds faster than at the
levels “LOW” and “MED” (see the following table).
The battery monitor mode can be selected as follows:
Switch on the cooler.
Press the “SET” button (fig. 3 4, page 3) three times.
Use the “UP +” (fig. 3 7, page 3) or “DOWN -” (fig. 3 6,
page 3) buttons to select the battery monitor mode.
Digital display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
The selected mode then appears in the display for a few sec-
onds. The display flashes several times before it returns to the
current temperature.
I
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V 10.1 V 11.4 V 11.8 V
Restartvoltage at 12 V 11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V 21.5 V 24.1 V 24.6 V
Restart voltage at 24 V 23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the bat-
tery monitor mode “HIGH”. If the cooler is connected to a supply
battery, the battery monitor mode “LOW” will suffice.