Instruction manual

Troubleshooting
38
9 Troubleshooting
10 Disposal
Place the packaging material in the appropriate recycling waste
bins wherever possible.
M
If you wish to finally dispose of the product, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
Fault Possible cause Suggested remedy
Device does not func-
tion, LED does
not glow.
Battery voltage is too
low.
Test the battery and charge it as needed.
No voltage present in the
AC voltage socket.
Try using another plug socket.
The device fuse is defec-
tive.
Replace the device fuse, see “Replacing
the device fuse” on page 36.
The integrated mains
adapter is defective.
This can only be repaired by an author-
ised repair centre.
The device does not
cool (plug is inserted,
“POWER” LED is lit).
Defective compressor. This can only be repaired by an author-
ised customer services unit.
The device does not
cool (plug is inserted,
“POWER” LED flashes
orange, display is
switched off).
Battery voltage is too
low.
Test the battery and charge it as needed.
The display shows an
error message (e.g.
“Err1”) and the appli-
ance does not cool.
The appliance has
switched off due to an
internal fault.
This can only be repaired by an author-
ised repair centre.
_CF-80_110.book Seite 38 Montag, 20. September 2010 10:40 10