Instruction manual
EN
CoolFreeze Operation
33
CDF18:
CDF26, CDF36, CDF46:
I
CDF26: Setting the battery monitor mode
This is how to select the battery monitor mode:
➤ Switch on the cooler.
➤ Press the “SET” button three times.
➤ Use the “+” and “–” buttons to select the battery monitor mode.
✓ The selected mode then appears in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
Battery monitor mode LOW HIGH
Switch-off voltage at 12 V
10,2 V ± 0,3 V 11,2 V ± 0,3 V
Restart voltage at 12 V
11,2 V ± 0,3 V 12,2 V ± 0,3 V
Switch-off voltage at 24 V
22,0 V ± 0,3 V 23,9 V ± 0,3 V
Restart voltage at 24 V
23,3 V ± 0,3 V 25,1 V ± 0,3 V
Battery monitor mode LOW MED HIGH
Switch-off voltage at 12 V
10,1 V 11,4 V 11,8 V
Restart voltage at 12 V
11,1 V 12,2 V 12,6 V
Switch-off voltage at 24 V
21,5 V 24,1 V 24,6 V
Restart voltage at 24 V
23,0 V 25,3 V 26,2 V
NOTE
When the cooler is supplied by the starter battery, select the bat-
tery monitor mode “HIGH”. If the cooler is connected to a supply
battery, the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC mains, set the bat-
tery monitor to the “LOW” position.