Safety Data Sheet (1907/2006/EC)
Material: 60003739
ELASTOSIL® A33
IVORY
Version: 2.5 (GB) Date of print: 29.05.2017 Date of last alteration: 24.11.2016
Page: 6/10
SECTION 10: Stability and reactivity
10.
10.1 10.3
Reactivity; Chemical stability; Possibility of hazardous reactions
10.2 10.3
10.3 10.3
If stored and handled in accordance with standard industrial practices no hazardous reactions are known.
Relevant information can possibly be found in other parts of this section.
10.4
Conditions to avoid
Heat, open flames, and other sources of ignition.
10.5
Incompatible materials
none known
10.6
Hazardous decomposition products
Measurements have shown the formation of small amounts of formaldehyde at temperatures above about 150 °C (302 °F)
through oxidation.
SECTION 11: Toxicological information
11.
11.1
Information on toxicological effects
11.1.1
Acute toxicity
Assessment:
For this endpoint no toxicological test data is available for the whole product.
Acute toxicity estimate (ATE):
ATE
mix
(oral): > 5000 mg/kg
ATE
mix
(dermal): > 5000 mg/kg
11.1.2
Skin corrosion/irritation
Assessment:
Irritation of the skin must be expected. Due to a strong adherence to the skin symptoms of skin corrosion cannot be excluded after
removing the substance mechanically.
Product details:
Result/Effect
Species/Test system
Source
not corrosive
Corrositex
Conclusion by
analogy
11.1.3
Serious eye damage / eye irritation
Assessment:
For this endpoint no toxicological test data is available for the whole product.
11.1.4
Respiratory or skin sensitization
Assessment:
For this endpoint no toxicological test data is available for the whole product.
11.1.5
Germ cell mutagenicity
Assessment:
For this endpoint no toxicological test data is available for the whole product.
11.1.6
Carcinogenicity
Assessment:
For this endpoint no toxicological test data is available for the whole product.