Datasheet

Safety Data Sheet (1907/2006/EC)
Material: 60003739
ELASTOSIL® A33
IVORY
Version: 2.5 (GB) Date of print: 29.05.2017 Date of last alteration: 24.11.2016
Page: 4/10
Precautions against fire and explosion:
Flammable vapors may accumulate and form explosive mixtures with air in containers, process vessels, including partial, empty
and uncleaned containers and vessels, or other enclosed spaces. Keep away from sources of ignition and do not smoke. Take
precautionary measures against electrostatic charging. Cool endangered containers with water.
7.2
Conditions for safe storage, including any incompatibilities
Conditions for storage rooms and vessels:
Observe local/state/federal regulations.
Advice for storage of incompatible materials:
Observe local/state/federal regulations.
Further information for storage:
Store in a dry and cool place. Store container in a well ventilated place.
7.3
Specific end use(s)
No data available.
SECTION 8: Exposure controls/personal protection
8.
8.1
Control parameters
Maximum airborne concentrations at the workplace:
CAS No.
Material
Type
mg/m
3
ppm
Dust fract.
Fibre/m
3
108-91-8
Cyclohexylamine
OEL
41,0
10,0
-
8.2
Exposure controls
8.2.1
Exposure in the work place limited and controlled
General protection and hygiene measures:
Observe standard industrial hygiene practices for the handling of chemical substances. Do not inhale gases/vapours/aerosols.
Use with adequate ventilation. Avoid contact with eyes and skin. Preventive skin protection recommended. Remove
contaminated, soaked clothing immediately. Clean work areas regularly. Provide emergency shower and eye-bath. Do not eat,
drink or smoke when handling.
Personal protection equipment:
Respiratory protection
In case of mist, spray or aerosol exposure wear suitable personal respiratory protection and protective suit. Suitable respiratory
equipment: Respirator with a full face mask, according to acknowledged standards such as EN 136.
Recommended Filter type: Combined filter type A-P2 (certain organic gases and vapors with boiling point > 65°C; particles),
according to acknowledged standards such as EN 14387
Observe the equipment manufacturer's information and wear time limits for respirators.
Eye protection
tight fitting protective goggles .
Hand protection
Gloves are required at all times when handling the material.
Recommended glove types: Protective gloves made of butyl rubber
thickness of the material: > 0,3 mm
Breakthrough time: > 480 min
Recommended glove types: Protective gloves made of nitrile rubber
thickness of the material: > 0,4 mm
Breakthrough time: 10 - 30 min
Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves.
Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion,
and the contact time. Note that, due to the numerous external influences (such as temperature), a chemically resistant protective
glove in daily use may have a service life that is considerably shorter than the measured break through time.