Use and Care Manual
wc_tx003294gb_FM10.fm
41
Rammer
Operation
4.9 Low Oil Shut-Off Switch—Honda
Overview
The low oil shutoff switch is designed to prevent engine damage caused by an
insufficient amount of oil. When starting the engine, an illuminated indicator (a)
notifies the operator that the engine oil level is low.
4.10 Emergency Shutdown Procedure
Procedure
If a breakdown or accident occurs while the machine is operating, follow the
procedure below:
1. Reduce engine speed to idle.
2. From the idle position, push the throttle to the right, then forward to the OFF
position. The engine will stop and the fuel valve will close.
3. Contact the rental yard or machine owner for further instructions.
wc_gr011882
a
Condition Engine oil level status Required action
■ Indicator does not
flash and engine
starts
Engine oil level is
acceptable
None
■ Indicator flashes
slowly
■ Engine does not start
Engine oil level is low Add engine oil. See
Technical Data for
quantity and type.