Replacement Part List

72_73
Mobile Generators (Tier 4i)
The perfect range of machines
to meet market and job site
needs with Tier 4i latest diesel
engine emission technology.
G 14
G 14 T4i G 25 T4i G 50 T4i
TECHNICAL DATA
SKID MOUNTED
Length x width x height in 69 x 36 x 41 76.6 x 35 x 44.5 96.25 x 38 x 53
Operating weight lbs 1603 2332 3783
Dry/Shipping weight lbs 1435/1451 1911 3178
GENERATOR WITH TRAILER
Length x width x height in 116 x 61 x 67 133 x 60 x 69 160 x 67.5 x 80
Operating weight lbs 1951 2802 4663
Prime output kW/kVA 13.5/13.5 19.5/24.4 38/48
Standby output kW/kVA 14.2/14.2 20.4/25.5 42/53
AC voltage single phase 120, 127, 139, 240, 254, 277V adjustable
three phase 208, 220, 240, 416, 440, 480V reconnectable
Frequency Hz 60 60 60
Power factor 1~ / 3~ 1.0 1.0/0.8 1.0/0.8
Voltage regulation
no load to full load % ±1.5 ±1 ±1
steady state ±0.2 ±0.2
Insulation class H H H
Sound level at max. load dB(A) 63 at 23 ft 63 at 23 ft 66.3 at 23 ft
Engine type Kubota Isuzu John Deere
Displacement in³ 100.5 133 275
Operating speed rpm 1800 1800 1800
Rated standby power hp @ rpm 24.3 @ 1800 35.4 @ 1800 74 @ 1800
at rated speed
Fuel tank capacity gal 21.4 58.4 84
Fuel consumption gal/h 1.34 1.8 3.4
(at continuous load)
Battery 12V/650CCA 12 V/750 CCA 12V/750 CCA
Trailer hitch type 2-inch Ball 2-inch Ball 3-inch Pintle
AC receptacles
120V - 20 amp GFI duplex 3 2 2
120/240V - 50 amp twist lock 1 2 3
120/240V - 30 amp twist lock 1 - -