Instructions / Assembly
Technical Data PD 2A / PD 3A
44 wc_td000379gb.fm
7.2 Pump
7.3 Sound Measurements
The required sound specification, Paragraph 1.7.4.u of 2006/42/EC Machinery
Directive, is:
the guaranteed sound power level (L
WA
) = 97 dB(A).
the sound pressure level at operator’s location (L
pA
):
PDT 2 = 85, PDI 2 = 85, PDT 3 = 85, PDI 3 = 85
These sound values were determined according to ISO 3744 for the sound power
level (L
WA
) and ISO 6081 for the sound pressure level (L
pA
) at the operator’s
location.
Machine PDI 2/PDT 2 PDI 3/PDT 3
Suction and discharge hose diameter mm (in.) 50 (2) 75 (3)
Operating weight kg (lb) 59 (131) 63 (140)
Maximum discharge head m (ft) 7.6 (38) 7.6 (38)
Maximum flow rate L/min
(gpm)
189
(50)
333
(88)
Maximum suction lift m (ft) 6.1 (20) 6.1 (20)
Maximum solid size diameter mm (in.) 38 (1.5) 41 (1.625)