Instructions / Assembly

Maintenance PSG2 500
26 wc_tx002007gb.fm
5.6 Disassembly
Note: To enhance serviceability, the PSG2 500 has been designed so
that the entire pump portion illustrated below can be disassembled with
a 12mm box wrench.
.
Stand the pump upside down with the discharge connection facing
downward during disassembly and reassembly. Exercise care to
prevent the pump from tipping, which may lead to injury..
5.6.1 Remove the three hex bolts with washers (1), then remove the strainer
(2) and suction cover (3).
5.6.2 Remove the hex nut / spring / washer assembly (4).
5.6.3 Remove the impeller (5), pump casing (6), shaft sleeve (7), and the V-
ring (8).
.
A worn impeller may have sharp edges that can cause injury, and
should be handled with care.
CAUTION
WARNING
8
7
6
5
1
2
3
4
wc_gr004650