Product Manual
wc_tx003607gb_FM10.fm
68
General Maintenance RD7
5.4 Lubricating the Back-up Stop Mechanism
When
Check daily. Clean and reapply grease as necessary.
Overview
To ensure proper operation and component life of the back-up stop mechanism,
apply grease to the metal components at the base of the forward/reverse control
lever. Regular cleaning and lubrication is essential for keeping the machine in
serviceable condition.
Procedure
1. Pull the forward/reverse control lever towards the operator to the reverse
position.
2. Press down the back-up stop pad to expose the travel plunger (a).
3. Clean any dirt or debris from the base of the forward/reverse control lever and
the drive disconnect (b).
4. Apply grease to the tip of the travel plunger (a) and between the drive
disconnect (b).
wc_gr014148
b
a