wc_tx003606gb_FM10.fm
52
Operation RD7
2. Check that the exciter lever (b) is in the OFF position.
3. Set the throttle lever (c) to the high position.
4. Move the decompression lever (d) to a position that is approximately halfway
between (d
0
) and (d
1
).
5. Insert the engine crank (e) into the guide sleeve (f).
6. Turn the engine over with the engine crank until it is felt to rotate more freely
(10–20 turns of the engine crank).
7. Clean around the cover of the metering device (g), then:
remove the cover (h)
fill with free-flowing lubricating oil (j) until the level reaches the upper rim
press the cover on firmly
Note: Two filling operations in succession are needed.
8. Turn the decompression lever until limit stop (d
1
).
This procedure continues on the next page.
WARNING
Personal injury hazard. Injury may result if the engine should backfire.
Stand alongside the engine, facing the back of the machine. Do not stand in any
other position.
Maintain turning force during the entire hand-starting operation.
wc_gr010225
h
g
j