Operation RD12A/12K
Water check
valve
The water spray system includes a water check valve (d) located between the
water pump and the spray bars. This water check valve prevents water from
draining out of the tank through the water system.
6.16 Using the Backup Alarm (if equipped)
Location
The backup alarm (a) is located on the rear of the machine.
Operation
Start the engine and move the forward/reverse lever to the reverse position. The
backup alarm should sound immediately. The backup alarm will continue to sound
until the forward/reverse lever is moved to the neutral position or to the forward
position.
Note: If the backup alarm does not sound, make the necessary repairs before
using the roller.
wc_gr015174
d
a
wc_gr014990