Operator`s manual
Operation RD 27
wc_tx000425gb.fm 32
4.13 Exciter System
See Graphic: wc_gr002309
The machine has exciters on each drum. The exciters are driven by
gear-type hydraulic motors. The exciter motors are fed by a fixed-
displacement, gear-type hydraulic pump. The exciters are electrically
controlled. A switch (l) on the control console is used to select between
no vibration, front drum only vibration, or both drum vibration. When
activated, a light (i) on the control panel illuminates. A separate switch
(m) on the forward-reverse lever activates the electrical circuit that
controls exciter operation. The vehicle chassis is isolated from
vibrations by a series of shockmounts.
Exciter selector switch
Use the selector switch (l) to select the desired vibration mode:
Position 1 - vibration on front drum only.
Position 2 - vibration on both drums.
Exciter ON/OFF switch
To start vibration, press button (m).
To stop vibration, press button (m) again.
CAUTION: Do not leave the vibration running when the vehicle is to
remain stationary for some time. Leaving the exciter on for a prolonged
period when the machine is stationary may damage the exciter.
wc_gr002309
1
2
m
l
i