Operator`s manual
Technical Data RD 27
wc_td000148gb.fm 18
3.4 Sound Measurements
The operating sound level, measured per the requirements of
Appendix 1, Paragraph 1.7.4.f of the EC-Machine Regulations, is:
• the guaranteed sound power level (L
WA
) = 106 dB(A).
• the sound pressure level at operator’s location (L
pA
) = 84 dB(A).
This sound value was determined according to ISO 3744 for the sound
power level (L
WA
).
3.5 Measurements of Operator Exposure to Vibration
The operator of this machine should expect to be exposed to vibration
levels listed below when using the machine in performance of its
normally intended function:
• Hand/arm vibration levels do not exceed 2.5 m/s
2
. This is the
representative value of the weighted root mean square (rms)
acceleration to which the hands and arms are subjected. The
weighted rms value measured according to ISO 5349-1 is 1.89
m/s
2
.
• Whole body vibration levels do not exceed 0.5 m/s
2
. This is the
representative value of the root mean square (rms) acceleration
to which the whole body is subjected. The weighted rms value
measured according to ISO 2631-1 is 0.209 m/s
2
.
The results are compliant to the limit and action vibration values (hand/
arm and whole body) as specified in European directive 2002/44/EC.