Maintenance PSR1 500
24 wc_tx002008gb.fm
Note: Worn lubricant and other waste products should be disposed of
by a qualified agent, in accord with applicable laws. The oil plug gasket
should be replaced each time the lubricant is inspected or changed.
Replacement Parts
The table lists the parts that need to be replaced periodically. Replace
these using the recommended frequency as a guideline.
Ref. Description Ref. Description
1. Oil inlet 3. Oil plug
2. Gasket 4. Allen wrench
Pump Model Lubricant Capacity
PSR1 500 150 ml (5.1 fl. oz.)
Part Replacement Frequency
Mechanical seal When lubricant in oil compartment becomes milky.
Oil (Turbine oil VG 32) Every 2,000 hours or 12 months, whichever comes first.
Packing Each time pump is disassembled or inspected.
V-ring When ring is worn, or each time pump is disassembled
or inspected.
Shaft sleeve When it becomes worn.