Product Manual
Installation PS3 1500 / PS3 2200
18 wc_tx001974gb.fm
3.7 Changing the Operating Voltage
The operating voltage of the motor can be changed from 110V to
220V depending on the available power source.
Requirements
• Pump disconnected from the power source
• Hand tools (screwdriver and wrench)
Procedure
Follow the procedure below to change the operating voltage of the
motor.
3.7.1 Remove the four bolts (c), lockwashers (d), and flat washers (e) that
fasten the housing cover (j) to the motor bracket.
3.7.2 Carefully lift the housing cover.
NOTICE: Avoid entangling the power cord lead wires with internal compo-
nents such as the centifugal switch (p) or the capacitor (o). Be careful not to
damage the O-ring (w) while lifting the housing cover.
3.7.3 Support the housing cover so that it allows access to the terminal box
(q).
WARNING
Electric shock hazard.
f Ensure that the pump is disconnected from the power source before changing
the operating voltage.
wc_gr008856
p