Repair manual
PS2 500, PSA2 500 Repair
Repair.fm 71
16.Install oil plug gasket (ad) over oil plug (ae) in the correct
orientation.
See graphic wc_gr000450.
17.Screw plug with gasket (ad & ae) into oil housing. Tighten oil plug
(ae).
18.Pre-test pump to verify proper operation.
19.Performance test pump. Test results should be:
PS2 500
PSA2 500
Maximum head > 10.36m (34ft)
Maximum volume > 200.6 ltr/min (53gpm)
Amperage @110V <
full load 6.4A
start 13.1A
Amperage @ 220V <
full load 3.2A
start 8.4A
Maximum head > 10.36m (34ft)
Maximum volume > 200.6 ltr/min (53gpm)
Amperage @ 110V <
full load 6.4A
start 13.1A
wc_gr000450
ad
ae