Repair manual

Repair PS2 500, PSA2 500
Repair.fm 68
—Capacitor can be re-used when the test indicator shakes once
and comes back slowly.
—Replace capacitor when the test indicator shakes continuously
and comes back quickly.
Test Relay Unit–PSA2 500 Only
The pump starts operating when there is current flowing between the
two relay unit electrodes. Hold a screw driver so it touches both
electrodes simultaneously, then test resistance using a Megger tester.
6.3.1.4 Power Supply Reassembly
Note: If, upon inspection and testing, a pump component requires
replacement, use only original manufacturer’s replacement
cables complete with anti-wicking block assembly and
certified for submersible use.
Note: Use only new gaskets and o-rings when reassembling pump.
wc_gr0000438