6.3.1.2 Power Supply Inspection
1. Measure cable length. The specified cable length is 996 cm (392
"),
subject to user’s specific application requirements.
—Replace cable if measured length is less than 797 cm (314
").
2. Inspect insulation materials of the power supply cable and wires for
cuts, cracking, hardening, abrasive wear or any other condition
where short circuit or water leaks are possible.
3. Inspect power supply cable and wires for broken connectors.
— Replace cable if continuity tests prove the conductors are
broken.
4. Inspect sheath for cuts, gouges, cracking, hardening or abrasive
wear.
—Replace power supply cable if outer sheath is damaged or
exposing interior insulation or protective materials. No tape
repair is permitted.
5. Visually inspect capacitor (q).
—Replace part if there is damage to insulation or any evidence of
electrolyte leaking from capacitor.
—PSA2 500 only, inspect relay unit.
1 = Ground L = Blue
2 = Frame Grounding G = Green
3 = Main Coil W = White
4 = Capacitor B = Black
5=Aux.Coil R=Red
6 = Miniature Protector