Repair manual

Repair PS2 400
Repair.fm 60
See graphic wc_gr000408.
24.Reposition single ground wire (h) to motor bracket (n) and secure
with screw (i).
25.Feed red, green and white wires, and guide them through opening
of housing cover (l).
26.Align three holes of housing cover and assemble (finger tight) with
three washers (k) and three bolts (j). Alternately tighten each bolt
one-quarter turn until tight.
27.Connect red, green and white wire connection to matching colored
wires of power cable (p).
28.Holding power cable (p) slightly above housing cover (l),push
wires inside protruding boss until cover (s) is flush with boss.
29.Secure cover (s) with two bolts (r).
30.Pre-test pump to verify proper operation.
31.Performance test pump. Test results should be:
R=Red
L=Blue
B=Black
Maximum head > 10.06m (33ft)
Maximum volume > 170.3 ltr/min (45gpm)
Amperage @ 110V <
full load 5.7A
start 13.1A