Repair manual

PS2 400 Repair
Repair.fm 55
3. Hold the vacuum position for 10 seconds. The gauge should
remain absolutely stable.
—Replace mechanical seal upon failing vacuum test.
6.2.2.4 Motor Reassembly
Note: If, upon inspection and testing, a pump component requires
replacement, use only original manufacturer’s replacement
cables complete with anti-wicking block assembly and
certified for submersible use.
Note: Use only new gaskets and o-rings when reassembling pump.
1. Insert thin metal piece (cw) into recess of rubber plug (rp).
See graphic wc_gr000606.
2. With stator (aq) inside motor housing, tuck motor leads inside
motor frame (t) and turn upside down. Make sure wires are not
pinched and motor frame (t) sits on a clean, flat surface.
3. Pre-assemble rubber plug (rp). Insert thin metal piece (cw) into
recess. Flip over and push white bushing (wb) into place.
4. Apply a drop of clean pump oil to rubber plug (rp). Using thumb,
press into motor frame (j).
wc_gr000606
cw
wb
rp
cw
wb
rp