Repair manual

Repair PS2 400
Repair.fm 54
5. Visually inspect mechanical seal (ad) for wear, cracks or damage.
Look carefully at flexible components, replace if deformed.
Note: Pay particular attention to sealing faces that butt up against
each other. They are divided by a thin oil film which prevents
water from entering motor.Replace entire mechanical seal
(ad) if worn, damaged or cracked. Replace every 6,000 hours
of service or one year, whichever comes first.
6.2.2.3 Motor Testing
Test Stator Insulation Resistance
1. Dry stator (aq) thoroughly and allow it to cool before testing.
2. Measure resistance between stator’s lead wire and motor frame
using Megger tester.
—Replace stator (aq) if test results fall below 20 M.
Test Stator Continuity
Test continuity between phase wire ends.
—Replace stator if any breaks are found.
Test Wire Resistance
Measure resistance of each phase using Megger tester.
—Replace stator if test results fluctuate more that ±5% of
manufacturer’s specification.
Locked Rotor Current Test
Lock rotor (an) and apply 25% of rated voltage by lock transformer or
regulator.
—Current measurement test results must be similar to rated
current.
Test Oil Chamber Pressure
1. After installing mechanical seal, attach a vacuum pump to oil
housing.
2. Raise negative pressure inside the oil chamber to 60 cmHg (11.6
in.Hg).
IMPORTANT: DO NOT exceed 60 cmHg (11.6 in.Hg).
wc_gr000444
aq