Repair manual
PS2 400 Repair
Repair.fm 45
9. Remove three bolts (j), three washers (k) and housing cover (l).
10.Disconnect red, black and blue wire connections (wc) to capacitor
(o).
See graphic wc_gr000603.
6.2.1.2 Power Supply Inspection
1. Measure cable length. The specified cable length is 627.3cm
(247in), subject to user’s specific application requirements.
—Replace cable if measured length is less than 503cm (198in).
2. Inspect insulation materials of power cable and wires for cuts,
cracking, hardening, abrasive wear or any other condition where
short circuit or water leaks are possible.
3. Inspect power cable and wires for broken connectors.
—Replace power cable if continuity tests prove conductors are
broken.
4. Inspect sheath for cuts, gouges, cracking, hardening or abrasive
wear.
—Replace power cable if outer sheath is damaged or exposing
interior insulation or protective materials. No tape repair is
permitted.
5. Visually inspect capacitor (o).
—Replace part if there is damage to insulation or any evidence of
electrolyte leaking from capacitor.
wc_gr000603
o
wc