Repair manual
General Operation
wc_tx000111gb.fm 37
Note: On cable assembly handling, see Electrical Wiring.
Avoid dry operation, which will not only lower performance but can
cause the pump to malfunction, leading to electrical leakage and
shock.
4.3.2 Install the pump in a location with sufficient water level, where water
collects readily.
Note: See Operation (“Operating Water Level”) for the water level
necessary for operation.
Note: The discharge end of the hose should be located higher than the
water surface. If the end of the hose is submerged, water may flow
back to the pump when the pump is stopped; and if the hose end is
lower than the water surface, water may overflow when the pump is
turned off.
If large quantities of earth are sucked up, damage resulting from
friction in the pump can lead to current leakage and shock.
4.3.3 Use the pump in the upright position. To prevent the strainer from
becoming submerged in mud, causing it to suck in sand or debris,
mount it on a block or other firm base.
4.3.4 If used in a permanent installation where the pump is not readily
accessible after installation, please contact Wacker for a duplicate
nameplate to be installed at the wellhead or on the control box so that
it will be readily visible.
Performing electrical wiring
Electrical wiring should be performed by a qualified person in accord
with all applicable regulations. Failure to observe this precaution not
only risks breaking the law but is extremely dangerous.
Incorrect wiring can lead to electrical leakage, electrical shock or fire.
ALWAYS make sure the pump is equipped with the specified overload
protectors and fuses or breakers, so as to prevent electrical shock from
an electrical leak or pump malfunction.
Operate within the capacity of the power supply and wiring.
Grounding
DO NOT use the pump without first grounding it properly. Failure to
ground it can lead to electrical shock from a current leak or pump
malfunction.
DO NOT attach the grounding wire to a gas pipe, water pipe, lightening
arrestor or telephone grounding wire. Improper grounding can result in
electrical shock.
CAUTION
CAUTION
WARNING
WARNING
CAUTION