—If measured distance between impeller is greater than 0.5mm
(0.196in), pumping capacity drops.
—If measured distance between impeller is less than 0.3mm
(0.118in), impeller may contact volute, slow rotation, overload
motor and cause premature failure.
6.6.4.3 Impeller Reassembly
Note: Draining oil is not required to disassemble, inspect and
replace impeller. However, if further disassembly and testing
is required, drain oil.
Note: If upon inspection and testing, it is determined that a
component of the pump needs replacement, use only original
manufacturer’s replacement parts.
1. With the pump on its side, replace the key (bi) properly in the
keyway of the rotor shaft.
2. Align and install impeller (am) over keyway of rotor shaft.
Note: Impeller vanes may be very sharp due to excessive wear.
Handle with care.
wc_gr000598
bi
am