Repair manual

Repair PS2 1503, PS3 1503, PS2 2203, PS3 2203
Repair.fm 142
PS2 2203
PS3 2203
6.6.4 Impeller Disassembly, Inspection, Testing and
Reassembly
6.6.4.1 Impeller Disassembly
Note: Draining oil is not required to disassemble, inspect or replace
the impeller. However, if further disassembly and testing is
required, drain oil.
Maximum head > 30.5m (100 ft)
Maximum volume > 500 ltr/min (132gpm)
Amperage @ 200V <
full load 9.3A
start 73A
Amperage @ 440V <
full load 4.7A
start 36A
Amperage @ 575V <
full load 3.5A
start 28A
Maximum head > 20.4m (67 ft)
Maximum volume > 500 ltr/min (132gpm)
Amperage @ 200V <
full load 9.3A
start 73A
Amperage @ 440V <
full load 4.7A
start 36A
Amperage @ 575V <
full load 3.5A
start 28A