Repair manual

PS3 1500, PS3 2200 Repair
Repair.fm 121
PS3 1500, slide heat shrinks back over each the three exposed
wire connections and apply heat to collapse insulation material
around connection. Make sure any exposed wire or metal is
completely insulated. Allow time to cool before proceeding.
IMPORTANT: DO NOT use electrical tape in place of heat shrink.
PS3 2200, attach identical colored wires and secure each
connection with wire nut (m).
IMPORTANT: DO NOT use electrical tape in place of heat shrink.
42.Holding the power cable (s) directly above housing cover (j), push
three wires inside the pump, aligning the four mounting holes of the
cable casing. Secure with four bolts (k) and four washers (l).
43.Put one leg of the lifting handle (a) through the keyring/warning
plate, then align mounting holes to top of the housing cover (j).
Secure with two bolts (b).
Note: If keyring/warning plate is damaged, illegible or missing,
replace it.
44.Position gasket (i) and hose coupling (h) to housing cover and
secure with three bolts (f) and three washers (g).
—Sequentially tighten each of the three nuts one-quarter turn until
seal is tight and torque is distributed evenly.
45.Pre-test pump to verify proper operation.
46.Performance test pump. Test results should be:
PS3 1500
PS3 2200
Maximum head > 17.9m (59ft)
Maximum volume > 355.8 ltr/min (94gpm)
Maximum head > 21.9m (72ft)
Maximum volume > 416.3 ltr/min (110gpm)