6.5.1.3 Power Supply Testing
1. Air test the cable insulation for resistance using a Megger tester
between conductors.
—Replace power cable (S) if readings fall below 30 M.
2. Water test the cable insulation for resistance using a water tank.
This testing method may detect minute insulation flaws that the air
test will not.
3. Submerse the cable in a water tank with conductors on both ends
of cable above the water level. After 24 hours, test the cable
insulation using a Megger tester between conductors and metal
container.
—Replace power cable (s) if readings fall below 30 M.
4. Dry capacitor (o) thoroughly before testing.
IMPORTANT: If using heat gun, do not exceed temperatures of
140°F (60°C).
5. Set circuit tester to 100 Kat resistance and connect between
both terminals.
—Capacitor can be reused when the test indicator shakes once
and comes back slowly.
—Replace capacitor (o) when the test indicator shakes
continuously and comes back quickly.
wc_gr000586
s
wc_gr000587
o