Repair manual
PS2 750 Repair
Repair.fm 99
7. Measure distance between impeller and volute after assembly.
Keep a recommended clearance of 0.3–0.5mm (0.118–0.196in).
—If measured distance between impeller is greater than 0.5mm
(0.196in), pumping capacity drops.
—If measured distance between impeller is less than 0.3mm
(0.118in), impeller may contact volute and slow rotation,
overload motor causing premature failure.
8. Position strainer (ap) over three protruding stud bolts and secure
with three nuts (ar).
9. Pre-test pump to verify proper operation.
10.Performance test pump. Test results should be:
Maximum head > 15.5m (51ft)
Maximum volume > 234.7 ltr/min (62gpm)