PS 2 750 POWER SOURCE SINGLE PHASE
If connected to a circuit protected by a fuse, use a time-delay fuse with
this pump.
Ref. Description Ref. Description
1. Circle Thermal Protector 5. Centrifugal Switch
2. Auxiliary Coil 6. Capacitor
3. Heater 7. Frame Grounding
4. Main Coil 8. Ground
Wire Colors
B Black V Violet Or Orange
G Green W White Pr Purple
L Blue Y Yellow Sh Shield
P Pink Br Brown LL Light Blue
R Red Cl Clear G/Y Green/Yellow
T Tan Gr Gray
R
R
2
W
W
R
5
7
4
8
G
L
L
6
R
1
1
2
G
3
3
wc
_
gr001203
CAUTION