Operator`s manual
PS 2 500 / PS 2 750 / PSA 2 500 Operation
wc_tx001986gb.fm 23
4.2 Operating Water Level
Do not operate the pump below the C.W.L. (Continuous running
Water Level) indicated below. Failure to observe this condition may
result in damage to the pump, current leakage or electrical shock.
See Graphic: wc_gr001225
Operating Water Level (PS 2 500, PS 2 750).
Operating water level (PSA2 500 only)
Starting the Pump:
This pump starts when water reaches the electrodes on the level relay
unit, conducting current between them.
Note: The necessary water level to operate the pump is 115 mm
(4-½") from the bottom of the pump. To force start the pump for trial
operation, short-circuit the electrodes (a) with a screwdriver (b) as
illustrated. Please keep items that may clog the pump (such as wires,
nails, cords, etc.) away from it.
Pump Model C.W.L.
PS 2 500 50mm (2”)
PS 2 750 100mm (4”)
CAUTION
C.W.L
PS 2 500, PS 2 750
115 mm (4-1/2")
a
b
wc
_
gr001225
PSA 2 500